Astm 1085 table chart hss hollow structural section square structural tube.
Steel tube column load chart.
Simple beam point load at any location.
Hss manufacturing methods the transformation of steel strip into hollow structural sections hss is the result of operations including forming welding and sizing.
The calculator can be utilized by anyone that knows the loading criteria of their application and whether the tube will be used as a beam or column.
H height w width t wall thickness i area moment of inertia s elastic section modulus.
Loading in the middle of the longest tube is a worst case for stress on a cage member.
Two point loads at one third points on a simple beam.
Enter the fy 46 ksi table page 9 for the 6 inch square erw hss.
Combined axial and bending load calculator.
Common square rectangle tube sizes square rect 14ga 1 8 3 16 1 4 5 16 3 8 1 2 5 8 1x1 1 04 1 44 1 25x1 25 1x1 5 1 32 1 84 1 5x1 5 1x2 1 60 2 25 3 35 4 07 1 75x1 75 1 5x2 1x2 5 1 88 2 66 3 99 2x2 1 5x2 5 1x3 2 16 3 05 4 31 5 41 1 5x3 2 45 3 48 5 07 2 5x2 5 2 79 3 90 5 60 7 11.
Vehicle load is a static distributed load in the middle of the longest tube and is 1 3 the tube length.
This specification covers cold formed welded carbon steel hollow structural sections hss for welded or bolted construction.
You can find in our tables both dimensions and properties for majority of the standard steel section like steel beams and columns channels angles steel hollow sections.
Read across the row at kl 16 ft.
Beam loads support force calculator calculate beam load and supporting forces.
This calculator will compute the acceptable allied galvanized steel tubing product size based on length and load criteria.
The welded tube 4 is cooled and then driven through a series of sizing stations which qualifies the tube s final dimensions.
Uniformly loaded beam overhanging post calculator.
The safety factors use the numbers in the table below for strength.
Steel i beam.
B to support a factored concentric load of 148 kips.
How to use the column load tables example 1 design the lightest 6 inch square erw hss column of f y 46 ksi astm a500 gr.
Rectangle structural tube per.
Euler s column formula buckling of columns.
The largest effective length kl is 16 feet.
Rafter and ceiling joist forces.
He a steel beams properties of he a profiled.
Another simple column calculator.
Concrete columns estimate concrete volume required for concrete columns.
Square tube assumes bending with one side parallel to the load think square vs diamond.
H height w width t wall thickness i area moment of inertia s elastic section modulus.
British universal columns and beams properties of british universal steel columns and beams.
Simple beam point load at midspan.
Later we decided to open the tables for our visitors.
And note the following.
This specification covers cold formed welded carbon steel hollow structural sections hss for welded or bolted construction.
At first this part of the site was intended for internal use only.