A typical standing seam panel can be approximately 12 16 and 19 inches wide.
Standing seam metal roof edge detail.
Rake to metal wall detail.
A contractor can minimize the appearance of edge creep by using lap flashing hemming exposed edges when possible or using a paint pen on visible cut edges.
Standing seam consists of sheet metal roofing panels joined side by side and attached to the roofing deck with concealed fasteners.
Eave trim details for standing seam eave option 1 hem around eave cleat is installed then extended eave is hooked over cleat and finally the panel ribs are cut off and the flat part is hemmed around the extended eave trim.
This will keep weather out prevent lifting in high winds and provide a neat fin ished appearance.
Many details in a standing seam metal roof have folds or hemmed edges that conceal the cut edge of the metal.
Colonial seam continuous standing seam metal roof panel with an integral seam.
Standing seam metal roofing is defined as a concealed fastener metal panel system that features vertical legs and a broad flat area between the two legs.
Pac 150 180 double lock.
The general principles of attaching the upper and lower edges of the standing seam roofing are most thoroughly covered in the sections on drip edge pg 9 and ridge caps pg 11.
The recommended dimensions should be specified from the table below.
It s also described as having raised seams or vertical legs that rise above the level of the panel s flat area.
The panels can be roll formed at the job site or at your local roofing materials supply warehouse.
Pac 150 90 single lock.
Roof pitch the metal roofing panels shown in this manual require a mini.
Standing seam roofing is composed of preformed or field formed pans usually between 14 to 18 inches wide when finished.
These pans run parallel to the slope of the roof and are joined to adjacent pans with double locked standing seams.
Clipless one piece positive locking standing seam panel that provides a timeless roof appearance.
Corrosion will happen at some point in the lifetime of the roof.
The connecting point where the two separate metal panels meet forms a vertically pointed rib or a seam that is one inch to inch and a half high.
Panel extended eave cleat pancake head screw tube sealant add 1 to measurements.
Trimming and cutting steel panels the best devices for cutting steel panels across the profile are circular saws nibblers.
Deck w iso details.
This will keep weather out prevent lifting in high winds and provide a neat finished appearance.
The trim and roofing sheet should be fastened every 12 to 24 inches along the gable edge.
Perimeter roof edge systems brochure.
To provide a drip edge allow an overhang of 1 to 2 inches at the eave.